ABB ACS310-03E-34A1-4
Price on request
The individual quotation states the shipping method and costs for the item and destination.
The ABB CDP311 combines operation and display in one panel. Its LCD presents four lines with 20 characters each. Flat, labelled push-buttons provide navigation and input. Four keypad modes are available: Actual Signal Display, Parameter, Function and Drive Selection. Three actual signals can be shown simultaneously in Actual Signal Display mode. The fault history contains the five most recent faults. Operating commands include start, stop, changing the direction of rotation and setting the reference. Parameter mode allows parameters to be selected and values to be changed. Function mode includes upload, download and display-contrast adjustment. Drive Selection mode shows the drive type, its ID number and the number of connected drives. The factory-set panel ID of the CDP311 is 31. Communication uses Panel Link or the CDI-300 communication bus based on RS-485. The CDP311 is associated with the ACS 600 drive range and is also used with DCS-500B-, DCF-500B- and DCP-500B converters of the corresponding software generation. The panel can be mounted directly on the drive, on a control-cabinet door using a mounting kit, or remotely via a connection cable. Connection to the electronics is permitted while auxiliary power is present. The enclosure is 90 mm wide, 170 mm high and 30 mm deep. Net weight is 0.20 kg. The complete public variant designation remains CDP311. Its technical data include the display version, the four keypad modes, Panel Link and the relevant software generation. Delivery time is confirmed on request.
The item supplied will have the stated manufacturer or type number and the stated condition category. Serial number, manufacturing date, labels, colour, packaging and normal signs of use or storage may differ. Unless expressly confirmed, technical information is provided to identify the device type. The complete manufacturer or type number is decisive.
| Manufacturer | ABB |
|---|---|
| Product range | ACS 600 / DCS 500 |
| Manufacturer/order/identification number | CDP311 |
| Device type | Operator and control panel |
| Display | LCD |
| Display format | 4 lines with 20 characters each |
| Controls | Flat, labelled push-buttons |
| Keypad modes | Actual Signal Display, Parameter, Function and Drive Selection |
| Simultaneous actual-signal display | 3 actual signals |
| Fault history display | 5 most recent faults |
| Operating commands | Start, stop, direction and reference |
| Parameter function | Select parameters and change values |
| Function mode | Upload, download and display contrast |
| Drive Selection mode | Drive type, ID number and number of connected drives |
| Communication interface | Panel Link / CDI-300 based on RS-485 |
| Factory-set panel ID | 31 |
| Mounting methods | Directly on the drive, on a control-cabinet door or remotely by cable |
| Connection with electronics powered | Permitted |
| Dimensions | 90 × 170 × 30 mm (W × H × D) |
| Weight | 0.20 kg net |
Urgent requirement?
Send us the complete type number, destination and requested timing. We will assess whether the specific item can be supplied and which shipping options can be offered.
Any stated dispatch or delivery date is an estimate unless expressly confirmed as binding.
Contact us now!Manufacturer / EU responsible person
The LCD shows four lines with 20 characters each. Actual Signal Display, Parameter, Function and Drive Selection modes are available.
The panel measures 90 × 170 × 30 mm in width, height and depth. Net weight is 0.20 kg.
For the condition categories “Used, removed from an installation” and “New, old stock”, the contractual 14-day right of return in the event of a defect applies. The defect must occur within 14 calendar days after delivery and be reported in text form within the same period.
In particular, the REHA tamper-evident seal must remain fully intact and our RMA approval is required before return. In an accepted case, we decide between replacement and refund. Details in Section 11 of the Terms.
The shipping method, shipping cost and estimated delivery time are confirmed for the specific order. Depending on the item, destination and urgency, we can check parcel, express or freight shipping as well as collection.
A delivery date is binding only if we expressly confirm it as binding.
The payment terms stated in the checkout or order confirmation apply. Depending on the order and customer, payment is made in advance or against invoice.
International deliveries and deliveries to new customers are generally made against advance payment unless we expressly confirm another payment arrangement.
No. There is no general B2B right of return, exchange, cancellation or withdrawal. Incorrect or duplicate orders and a lack of suitability or compatibility with the customer’s installation are not covered by the contractual 14-day right of return in the event of a defect. Details in Section 12 of the Terms.
You may request an individual quotation for several items or larger quantities. We then check availability and pricing for the specific requirement; there is no entitlement to a quantity discount. Open the quick enquiry.
Yes. You can offer us automation and drive components for purchase. Please provide complete type numbers, quantities, condition details and photographs where possible.
After review, we will tell you whether a purchase is possible and on which terms. Learn more about selling industrial stock.
Receive a quotation by email
Use the form to request item-specific price, availability and estimated delivery information.