The Leuze AMS 348i 40, an optical distance measurement system of the AMS 300i series, detects distances of up to 40 m with a class 2 red laser at 655 nm. The measuring range extends from 200 to 40 000 mm; the resolution can be set between 0.001 and 10 mm. The accuracy is 2 mm, the reproducibility 0.9 mm at 3 sigma, and the temperature drift is 0.01 to 0.1 mm per Kelvin.
A measured value is calculated in 8 ms and output every 1.7 ms; the permissible travel speed is up to 10 m/s. Typical applications are the positioning of stacker cranes, electroplating systems, electric overhead conveyors and transfer cars as well as collision protection for cranes. As a bus interface, this version works with PROFINET RT Conformance Class B, has an integrated switch and transmits at 100 Mbit/s.
For this purpose, the M12 sockets BUS IN and BUS OUT, 4-pin D-coded, are available; power is supplied via the 5-pin M12 connector PWR, and another 5-pin socket serves as a service interface. It is powered with 18 to 30 V DC. The light spot is round and measures approximately 40 mm at a distance of 40 m. An LC display, four LEDs and a membrane keypad are used for on-site operation.
The housing made of die-cast zinc and aluminum with a glass cover for the optics achieves IP65 and protection class III; it is operated at −5 to 50 °C. It measures 84 × 166.5 × 159 mm and weighs 2.45 kg. Shipping from Germany to the United States and other international destinations.
Unless expressly confirmed, technical information is provided to identify the device type. The complete manufacturer or type number is decisive.
| Manufacturer | Leuze |
|---|---|
| Product series | AMS 300i |
| Manufacturer/ | AMS 348i 40 |
| Device type | optical distance measurement system (laser), AMS 300i series |
| Max. travel speed | 10 m/s |
|---|---|
| Supply voltage | 18 to 30 V DC |
| Measured value output | 1.7 ms, measured value calculation 8 ms |
|---|---|
| Interface | PROFINET RT, Conformance Class B, integrated switch, 100 Mbit/s |
| Connections | BUS IN and BUS OUT M12 4-pin D-coded, PWR M12 5-pin, SERVICE M12 5-pin |
| Protection rating / | IP65 / III |
|---|---|
| Ambient temperature | Operation −5 to 50 °C, storage −30 to 70 °C |
| Housing material | die-cast zinc/aluminum, glass optics cover |
| Mounting | Through-hole mounting |
| Dimensions | 84 × 166.5 × 159 mm |
|---|---|
| Weight | 2.45 kg |
| Measuring range | 200 to 40 000 mm |
|---|---|
| Resolution / | 0.001 to 10 mm adjustable / 2 mm |
| Reproducibility | 0.9 mm (3 sigma) |
| Light source | red laser 655 nm, laser class 2 |
| Operation and display | LC display, 4 LEDs, membrane keypad |
Urgent requirement?
Send us the complete type number, destination and requested timing. We will assess whether the specific item can be supplied and which shipping options can be offered.
Any stated dispatch or delivery date is an estimate unless expressly confirmed as binding.
Contact us now!Manufacturer / EU responsible person
200 to 40 000 mm with 2 mm accuracy and 0.9 mm reproducibility; the travel speed may be up to 10 m/s.
Via PROFINET RT with integrated switch and 100 Mbit/s at the BUS IN and BUS OUT connections.
For the condition categories “Used, removed from an installation” and “New, old stock”, the contractual 14-day right of return in the event of a defect applies. The defect must occur within 14 calendar days after delivery and be reported in text form within the same period.
In particular, the REHA tamper-evident seal must remain fully intact and our RMA approval is required before return. In an accepted case, we decide between replacement and refund. Details in Section 11 of the Terms.
The shipping method, shipping cost and estimated delivery time are confirmed for the specific order. Depending on the item, destination and urgency, we can check parcel, express or freight shipping as well as collection.
A delivery date is binding only if we expressly confirm it as binding.
The payment terms stated in the checkout or order confirmation apply. Depending on the order and customer, payment is made in advance or against invoice.
International deliveries and deliveries to new customers are generally made against advance payment unless we expressly confirm another payment arrangement.
No. There is no general B2B right of return, exchange, cancellation or withdrawal. Incorrect or duplicate orders and a lack of suitability or compatibility with the customer’s installation are not covered by the contractual 14-day right of return in the event of a defect. Details in Section 12 of the Terms.
You may request an individual quotation for several items or larger quantities. We then check availability and pricing for the specific requirement; there is no entitlement to a quantity discount. Open the quick enquiry.
Yes. You can offer us automation and drive components for purchase. Please provide complete type numbers, quantities, condition details and photographs where possible.
After review, we will tell you whether a purchase is possible and on which terms. Learn more about selling industrial stock.
Receive a quotation by email
Use the form to request item-specific price, availability and estimated delivery information.