Mitsubishi Electric FR-A820-00340-2-60
Price on request
Shipping carriers
MELSEC-F / FX2N Serial communication module
Price on request
Availability is checked individually.
The item comes from dismantled equipment. We have not carried out an electrical inspection or a comprehensive operational check. Signs of age, use, installation or removal may be present. 14-day right of return in the event of a defect. See Terms and Conditions
Do you have any questions?
Personal service
We are happy to help with processing, shipping or individual quotations. Simply contact us:
The individual quotation states the shipping method and costs for the item and destination.
The Mitsubishi Electric FX2N-232IF processes serial data between the PLC and an external RS-232C device via its own buffer memory. The special function block of the MELSEC-F family uses an asynchronous full-duplex connection without a fixed communication protocol. Typical counterparts named are, for example, computers, barcode readers or printers. The connection is designed as a point-to-point connection with one counterpart and has a maximum transmission distance of 15 m. Seven baud rates are available: 300, 600, 1.200, 2.400, 4.800, 9.600 and 19.200 baud.
The send and receive buffer holds 512 bytes or 256 words. The PLC accesses the buffer memory of the module with FROM and TO instructions. ASCII/HEX conversion is available for send and receive data. For order-related procurement with shipping from Germany to the United States and other international destinations, the FX2N-232IF is thus described by RS-232C, buffer memory and this data conversion. In interlink connection mode, data volumes above the buffer size can also be received: the module interrupts the request for further data while the PLC program reads out the receive buffer.
The remaining data stream is then accepted. The front 9-pin D-Sub connector carries the associated handshake signals in addition to send and receive data. The POWER, SD and RD indicators show supply, sending and receiving. Internally, the module requires 5 V DC at 40 mA from the PLC and externally 24 V DC with ±10 percent tolerance at 80 mA. Isolation is provided by optocouplers. Eight input or output points are occupied on the extension bus. For mechanical mounting, a 35-mm-DIN rail mount and two mounting holes are provided; the housing measures 55 × 90 × 85 mm.
Unless expressly confirmed, technical information is provided to identify the device type. The complete manufacturer or type number is decisive.
| Manufacturer | Mitsubishi Electric |
|---|---|
| Product series | MELSEC-F / FX2N |
| Manufacturer/order/ident number | FX2N-232IF |
| Device type | Serial communication module |
| Internal supply | 5 V DC / 40 mA from the PLC |
|---|---|
| External supply | 24 V DC ±10 % / 80 mA |
| Interface | RS-232C |
|---|---|
| Connection structure | 1:1 |
| Connection | 9-pin D-Sub connector |
| Mounting | 35-mm-DIN rail or two mounting holes |
|---|
| Dimensions | 55 × 90 × 85 mm (W × H × D) |
|---|---|
| Weight | approx. 0.3 kg |
| Transmission method | Full duplex, asynchronous, without fixed protocol |
|---|---|
| Transmission rate | 300–19.200 baud, seven selectable steps |
| Transmission distance | Maximum 15 m |
| Send/receive buffer | 512 bytes / 256 words |
| Data conversion | ASCII/HEX |
| PLC data exchange | FROM/TO instructions via buffer memory |
| Isolation | Optocoupler |
| Occupied I/O points | 8 points on the extension bus |
Urgent requirement?
Send us the complete type number, destination and requested timing. We will assess whether the specific item can be supplied and which shipping options can be offered.
Any stated dispatch or delivery date is an estimate unless expressly confirmed as binding.
Contact us now!Manufacturer / EU responsible person
The PLC reads and writes the buffer memory of the module with FROM and TO instructions. The send/receive buffer comprises 512 bytes or 256 words.
For the condition categories “Used, removed from an installation” and “New, old stock”, the contractual 14-day right of return in the event of a defect applies. The defect must occur within 14 calendar days after delivery and be reported in text form within the same period.
In particular, the REHA tamper-evident seal must remain fully intact and our RMA approval is required before return. In an accepted case, we decide between replacement and refund. Details in Section 11 of the Terms.
The shipping method, shipping cost and estimated delivery time are confirmed for the specific order. Depending on the item, destination and urgency, we can check parcel, express or freight shipping as well as collection.
A delivery date is binding only if we expressly confirm it as binding.
The payment terms stated in the checkout or order confirmation apply. Depending on the order and customer, payment is made in advance or against invoice.
International deliveries and deliveries to new customers are generally made against advance payment unless we expressly confirm another payment arrangement.
No. There is no general B2B right of return, exchange, cancellation or withdrawal. Incorrect or duplicate orders and a lack of suitability or compatibility with the customer’s installation are not covered by the contractual 14-day right of return in the event of a defect. Details in Section 12 of the Terms.
You may request an individual quotation for several items or larger quantities. We then check availability and pricing for the specific requirement; there is no entitlement to a quantity discount. Open the quick enquiry.
Yes. You can offer us automation and drive components for purchase. Please provide complete type numbers, quantities, condition details and photographs where possible.
After review, we will tell you whether a purchase is possible and on which terms. Learn more about selling industrial stock.
Receive a quotation by email
Use the form to request item-specific price, availability and estimated delivery information.