As a fieldbus card, the CFN21A extends the communication equipment of the MOVIDRIVE technology application inverters MDX90 and MDX91 with PROFINET. SEW-Eurodrive assigns the order number 28231694 to this version. The card forms the connection between the application inverter and higher-level automation, configuration or visualisation systems. Its Ethernet connection also enables direct access with the MOVISUITE engineering software for commissioning, diagnostics and parameterisation. For PROFINET data exchange, the interface supports both RT and IRT, i.e. Isochronous Realtime. Conformance Class C and Netload Class 3 characterise the communication properties of the card. The connection is made via RJ45, and the transmission rate is 100 Mbaud in full-duplex mode. An integrated Ethernet switch works according to the cut-through method; its latency is 5.5 µs. These specifications describe the network path of the fieldbus card and must be distinguished from the performance data of the inverter. The network configuration includes topology detection via LLDP as well as automatic addressing via LLDP and DCP. Media redundancy is supported via MRP. The shared device function is also part of the functional scope. For the specific order with shipping from Germany to the United States and other international destinations, CFN21A designates the PROFINET card with this network functionality and the order number 28231694. An integrated web server provides diagnostic values via a standard browser; access is via the IP address of the device. In addition to the cyclic PROFINET data exchange, this provides access paths for engineering and diagnostics. The power consumption of the fieldbus card is 2 W. A GSDML device description file belongs to the interface for integration into the configuration. The Ethernet communication and the MOVISUITE connection concern the link to the application inverter, while its power section remains a separate system component.
The item supplied will have the stated manufacturer or type number and the stated condition category. Serial number, manufacturing date, labels, colour, packaging and normal signs of use or storage may differ. Unless expressly confirmed, technical information is provided to identify the device type. The complete manufacturer or type number is decisive.
| Manufacturer | SEW-Eurodrive |
|---|---|
| Product series | MOVIDRIVE technology |
| Manufacturer/order/ident number | CFN21A |
| Device type | PROFINET fieldbus card |
| Module role and system assignment | MOVIDRIVE technology MDX90/MDX91 |
| Communication protocol | PROFINET RT and IRT |
| Power consumption | 2 W |
| Communication rate | 100 Mbaud, full duplex |
| Connection technology | RJ45 |
| PROFINET interface class | C |
| Interface: Netload Class | 3 |
| Function: topology detection | LLDP |
| Function: automatic addressing | LLDP, DCP |
| Communication: media redundancy | MRP |
| Communication function: Shared Device | Supported |
| Ethernet switch: communication method and latency | Integrated, cut through, latency 5.5 µs |
| Engineering and diagnostic interface | MOVISUITE via Ethernet; web server for diagnostics |
| Dimensions | approx. 30 × 120 × 100 mm |
| Weight (reference type not specified) | 0.08 kg |
Urgent requirement?
Send us the complete type number, destination and requested timing. We will assess whether the specific item can be supplied and which shipping options can be offered.
Any stated dispatch or delivery date is an estimate unless expressly confirmed as binding.
Contact us now!Manufacturer / EU responsible person
The fieldbus card supports RT and IRT as well as Conformance Class C and Netload Class 3.
Via Ethernet with MOVISUITE for commissioning, diagnostics and parameterisation. The integrated web server provides diagnostic values in the browser.
For the condition categories “Used, removed from an installation” and “New, old stock”, the contractual 14-day right of return in the event of a defect applies. The defect must occur within 14 calendar days after delivery and be reported in text form within the same period.
In particular, the REHA tamper-evident seal must remain fully intact and our RMA approval is required before return. In an accepted case, we decide between replacement and refund. Details in Section 11 of the Terms.
The shipping method, shipping cost and estimated delivery time are confirmed for the specific order. Depending on the item, destination and urgency, we can check parcel, express or freight shipping as well as collection.
A delivery date is binding only if we expressly confirm it as binding.
The payment terms stated in the checkout or order confirmation apply. Depending on the order and customer, payment is made in advance or against invoice.
International deliveries and deliveries to new customers are generally made against advance payment unless we expressly confirm another payment arrangement.
No. There is no general B2B right of return, exchange, cancellation or withdrawal. Incorrect or duplicate orders and a lack of suitability or compatibility with the customer’s installation are not covered by the contractual 14-day right of return in the event of a defect. Details in Section 12 of the Terms.
You may request an individual quotation for several items or larger quantities. We then check availability and pricing for the specific requirement; there is no entitlement to a quantity discount. Open the quick enquiry.
Yes. You can offer us automation and drive components for purchase. Please provide complete type numbers, quantities, condition details and photographs where possible.
After review, we will tell you whether a purchase is possible and on which terms. Learn more about selling industrial stock.
Receive a quotation by email
Use the form to request item-specific price, availability and estimated delivery information.