It provides 16 outputs for 24-V-DC loads and is divided into two isolated groups, each with eight outputs. The current requirement from the S7-400 backplane bus is typically 110 mA and a maximum of 160 mA at 5 V DC; a maximum of 30 mA is drawn from the load supply L+ without load. The typical power loss is 5 W. Documented identifiers and values: 6ES7; 422-1BH10-0AA0; 24 V; 2 A; 6 A; 25; 290; 210 mm; 600 g. The nominal current per output is 2 A; Siemens documents a permissible range of 5 mA to 2.4 A for the signal 1. The nominal load voltage is 24 V DC and may be between 20.4 and 28.8 V DC. For each supply voltage group, the total current is at 20 °C to 4 A and at 60 °C to 2 A. For DC actuators, a maximum lamp load of 10 W and up to 100 Hz switching frequency with ohmic load are specified. For inductive loads, a maximum of 0.2 Hz applies at 1 A or 0.1 Hz at 2 A. Unshielded cables may be up to 600 m long, shielded cables up to 1,000 m long. Siemens 6ES7 422-1BH10-0AA0 is a digital output module SM 422 for the SIMATIC S7-400 automation system. With 25 x 290 x 210 mm and approximately 600 g, the module corresponds to the narrow S7-400 design. The documented value for Product series is SIMATIC S7-400.
The item supplied will have the stated manufacturer or type number and the stated condition category. Serial number, manufacturing date, labels, colour, packaging and normal signs of use or storage may differ. Unless expressly confirmed, technical information is provided to identify the device type. The complete manufacturer or type number is decisive.
| Manufacturer | Siemens |
|---|---|
| Product series | SIMATIC S7-400 |
| Manufacturer/order/identification number | 6ES7 422-1BH10-0AA0 |
| Device type | Digital output module SM 422 |
| Outputs | 16 digital outputs in two groups of 8 each |
| Electrical isolation | in groups via optocouplers |
| Rated load voltage | 24 V DC; permissible range 20.4 to 28.8 V DC |
| Output current | 2 A nominal value; 5 mA to 2.4 A at signal 1 |
| Total current per group | 4 A at 20 °C; 2 A at 60 °C |
| Residual current at signal 0 | maximum 0.5 mA |
| Lamp load | maximum 10 W |
| Switching frequency | maximum 100 Hz with ohmic load; 0.2 Hz at 1 A or 0.1 Hz at 2 A inductive |
| Switching delay | maximum 1 ms |
| Short circuit protection | electronic; response range 2.8 to 6 A |
| Cable length | up to 600 m unshielded and 1,000 m shielded |
| Status display | green LED per channel |
| Diagnostics and interrupts | not supported |
| Current consumption | typically 110 mA and maximum 160 mA from the 5-V-DC backplane bus; maximum 30 mA from load supply L+ without load |
| Dimensions | 25 x 290 x 210 mm |
| Weight | approx. 600 g |
Urgent requirement?
Send us the complete type number, destination and requested timing. We will assess whether the specific item can be supplied and which shipping options can be offered.
Any stated dispatch or delivery date is an estimate unless expressly confirmed as binding.
Contact us now!Manufacturer / EU responsible person
The full manufacturer and type number 6ES7 422-1BH10-0AA0 is decisive for the order. Selection of the required version and verification for the customer’s installation remain the responsibility of the customer or its qualified personnel and should be based on the manufacturer documentation.
For the condition categories “Used, removed from an installation” and “New, old stock”, the contractual 14-day right of return in the event of a defect applies. The defect must occur within 14 calendar days after delivery and be reported in text form within the same period.
In particular, the REHA tamper-evident seal must remain fully intact and our RMA approval is required before return. In an accepted case, we decide between replacement and refund. Details in Section 11 of the Terms.
The shipping method, shipping cost and estimated delivery time are confirmed for the specific order. Depending on the item, destination and urgency, we can check parcel, express or freight shipping as well as collection.
A delivery date is binding only if we expressly confirm it as binding.
The payment terms stated in the checkout or order confirmation apply. Depending on the order and customer, payment is made in advance or against invoice.
International deliveries and deliveries to new customers are generally made against advance payment unless we expressly confirm another payment arrangement.
No. There is no general B2B right of return, exchange, cancellation or withdrawal. Incorrect or duplicate orders and a lack of suitability or compatibility with the customer’s installation are not covered by the contractual 14-day right of return in the event of a defect. Details in Section 12 of the Terms.
You may request an individual quotation for several items or larger quantities. We then check availability and pricing for the specific requirement; there is no entitlement to a quantity discount. Open the quick enquiry.
Yes. You can offer us automation and drive components for purchase. Please provide complete type numbers, quantities, condition details and photographs where possible.
After review, we will tell you whether a purchase is possible and on which terms. Learn more about selling industrial stock.
Receive a quotation by email
Use the form to request item-specific price, availability and estimated delivery information.