From a nominal input voltage of 100 to 240 V AC, ABB SU/S30.640.2 generates a KNX bus voltage of 30 V DC with a rated current of 640 mA. The permissible wide-range input extends from 85 to 265 V AC at 50 or 60 Hz. An integrated choke isolates the supplied bus line from the power supply; the bus voltage range is 21 to 31 V DC. An overload current of 900 mA is specified for load peaks, while power loss remains below 10 W and power consumption below 60 VA. The uninterruptible version has a battery connection including a temperature sensor. Up to two parallel 12-V lead-gel batteries of equal capacity can be connected; the documented range extends from 1 Ah to twice 17 Ah. Separate LEDs indicate mains voltage, battery status, KNX bus voltage and overload. A potential-free changeover contact additionally signals mains failure, battery faults, and overvoltage, overload or short circuit on the bus line. The device belongs to the ABB i-bus KNX range and carries order number 2CDG110275R0011. As a compact modular installation device in pro M design, it occupies eight space units on a 35-mm mounting rail. IP20 protection, protection class II and an operating temperature range of −5 to +45 °C define the environmental limits. Dimensions are 90 × 140 × 63.5 mm and device weight is 0.398 kg.
Example image – The item supplied will have the stated manufacturer or type number and the stated condition category. Serial number, manufacturing date, labels, colour, packaging and normal signs of use or storage may differ. Specifications
| Manufacturer | ABB |
|---|---|
| Product range | ABB i-bus KNX |
| Manufacturer/order/identification number | SU/S30.640.2 |
| Order number | 2CDG110275R0011 |
| Mains voltage | 100–240 V AC; wide range 85–265 V AC |
| Mains frequency | 50/60 Hz |
| Power consumption | < 60 VA |
| Power loss | < 10 W |
| KNX output voltage | 30 V DC |
| Bus voltage range | 21–31 V DC |
| KNX rated current | 640 mA |
| Bus overload current | 900 mA |
| Battery voltage | 12 V DC |
| Battery connection | maximum 2 lead-gel batteries in parallel |
| Battery capacity | 1 Ah to 2 × 17 Ah |
| Bus connection | 1 KNX line with integrated choke |
| Degree of protection | IP20 |
| Mounting | 35-mm mounting rail to EN 60715; 8 space units |
| Dimensions | 90 × 140 × 63.5 mm (H × W × D) |
| Weight | 0.398 kg |
Urgent requirement?
Shipping options
Send us the complete type number, destination and requested timing. We will assess whether the specific item can be supplied and which shipping options can be offered.
Any stated dispatch or delivery date is an estimate unless expressly confirmed as binding.
Contact us now!Product safety
Manufacturer / EU responsible person
What KNX output data does ABB SU/S30.640.2 provide?
The power supply provides 30 V DC with a rated current of 640 mA for one KNX line. The bus voltage range is 21 to 31 V DC.
Which battery connections does SU/S30.640.2 have?
Connections are provided for up to two parallel 12-V lead-gel batteries of equal capacity and for a temperature sensor used to regulate the charging voltage.
What applies if an item develops a defect within 14 days?
For the condition categories “Used, removed from an installation” and “New, old stock”, the contractual 14-day right of return in the event of a defect applies. The defect must occur within 14 calendar days after delivery and be reported in text form within the same period.
In particular, the REHA tamper-evident seal must remain fully intact and our RMA approval is required before return. In an accepted case, we decide between replacement and refund. Details in Section 11 of the Terms.
Which shipping methods and delivery times are available?
The shipping method, shipping cost and estimated delivery time are confirmed for the specific order. Depending on the item, destination and urgency, we can check parcel, express or freight shipping as well as collection.
A delivery date is binding only if we expressly confirm it as binding.
Which payment terms apply?
The payment terms stated in the checkout or order confirmation apply. Depending on the order and customer, payment is made in advance or against invoice.
International deliveries and deliveries to new customers are generally made against advance payment unless we expressly confirm another payment arrangement.
Can I return an item ordered incorrectly or found incompatible?
No. There is no general B2B right of return, exchange, cancellation or withdrawal. Incorrect or duplicate orders and a lack of suitability or compatibility with the customer’s installation are not covered by the contractual 14-day right of return in the event of a defect. Details in Section 12 of the Terms.
Can I request individual pricing for several items?
You may request an individual quotation for several items or larger quantities. We then check availability and pricing for the specific requirement; there is no entitlement to a quantity discount. Open the quick enquiry.
Do you also purchase industrial spare parts?
Yes. You can offer us automation and drive components for purchase. Please provide complete type numbers, quantities, condition details and photographs where possible.
After review, we will tell you whether a purchase is possible and on which terms. Learn more about selling industrial stock.
Receive a quotation by email
Request price
Use the form to request item-specific price, availability and estimated delivery information.