A continuous output current of 24 A in the 380 to 440 V range identifies FC-102P11KT4E20H1 as a specific 11-kW power stage within the Danfoss VLT HVAC Drive FC 102 range. At the upper mains-voltage range of 441 to 480 V, the continuous value is 21 A. Values of 26.4 and 23.1 A respectively apply for 60 seconds in normal overload operation at 110 percent. The three-phase T4 version operates at 380 to 480 V AC and is rated at 15 hp at 460 V. Continuous input current is 24.2 A, and estimated power loss at maximum rated load is 392 W. E20 denotes the IP20 chassis in frame size B3. In this mechanical version, the frequency inverter measures 399 mm high, 165 mm wide and 249 mm deep; the depth increases to 262 mm with option A or B. Maximum unit weight is 12 kg. The H1 code identifies the integrated class A1/B or category C1 radio-interference suppression filter. The control card includes a USB-1.1 interface with a type-B socket and an RS-485 interface supporting up to 115 kBaud. The permitted ambient-temperature range extends from −25 to 50 °C without derating and up to 55 °C with derating. The complete designation distinguishes this combination of power stage, voltage class, enclosure and filter from adjacent FC-102 versions.
Example image – The item supplied will have the stated manufacturer or type number and the stated condition category. Serial number, manufacturing date, labels, colour, packaging and normal signs of use or storage may differ. | Manufacturer | Danfoss |
|---|---|
| Product range | VLT HVAC Drive FC 102 |
| Manufacturer/order/identification number | FC-102P11KT4E20H1 |
| Device type | Three-phase frequency inverter |
| Rated power | 11 kW / 15 hp at 460 V |
| Mains voltage | 3 × 380–480 V AC |
| Continuous output current | 24 A at 380–440 V; 21 A at 441–480 V |
| Maximum output current | 26.4 A at 380–440 V; 23.1 A at 441–480 V for 60 s |
| Overload capacity | 110 % for 60 s within 10 min |
| Continuous input current | 24.2 A |
| Estimated power loss | 392 W at maximum rated load |
| Enclosure version | E20, IP20 / chassis |
| Frame size | B3 |
| Radio-interference suppression filter | H1, class A1/B (category C1) |
| Control-card interfaces | USB 1.1 type B and RS-485 up to 115 kBaud |
| Analogue output | 0/4–20 mA; maximum load 500 Ω |
| Ambient temperature | −25 to 50 °C without derating; up to 55 °C with derating |
| Relative humidity | 5–95 %, non-condensing |
| Dimensions | 399 × 165 × 249 mm (H × W × D); 262 mm depth with option A/B |
| Weight | maximum 12 kg |
Urgent requirement?
Send us the complete type number, destination and requested timing. We will assess whether the specific item can be supplied and which shipping options can be offered.
Any stated dispatch or delivery date is an estimate unless expressly confirmed as binding.
Contact us now!Manufacturer / EU responsible person
Continuous output current is 24 A at 380 to 440 V and 21 A at 441 to 480 V. For 60 seconds, 26.4 and 23.1 A respectively are specified in normal overload operation.
The IP20 chassis measures 399 × 165 × 249 mm in height, width and depth. With option A or B, the depth is 262 mm; maximum unit weight is 12 kg.
For the condition categories “Used, removed from an installation” and “New, old stock”, the contractual 14-day right of return in the event of a defect applies. The defect must occur within 14 calendar days after delivery and be reported in text form within the same period.
In particular, the REHA tamper-evident seal must remain fully intact and our RMA approval is required before return. In an accepted case, we decide between replacement and refund. Details in Section 11 of the Terms.
The shipping method, shipping cost and estimated delivery time are confirmed for the specific order. Depending on the item, destination and urgency, we can check parcel, express or freight shipping as well as collection.
A delivery date is binding only if we expressly confirm it as binding.
The payment terms stated in the checkout or order confirmation apply. Depending on the order and customer, payment is made in advance or against invoice.
International deliveries and deliveries to new customers are generally made against advance payment unless we expressly confirm another payment arrangement.
No. There is no general B2B right of return, exchange, cancellation or withdrawal. Incorrect or duplicate orders and a lack of suitability or compatibility with the customer’s installation are not covered by the contractual 14-day right of return in the event of a defect. Details in Section 12 of the Terms.
You may request an individual quotation for several items or larger quantities. We then check availability and pricing for the specific requirement; there is no entitlement to a quantity discount. Open the quick enquiry.
Yes. You can offer us automation and drive components for purchase. Please provide complete type numbers, quantities, condition details and photographs where possible.
After review, we will tell you whether a purchase is possible and on which terms. Learn more about selling industrial stock.
Receive a quotation by email
Use the form to request item-specific price, availability and estimated delivery information.