International delivery

The individual quotation states the shipping method and costs for the item and destination.

Product description

Two load profiles determine the performance data of this MICROMASTER 440: in high-overload operation, 55 kW and 110 A output current are stated; in low-overload operation, 75 kW and 145 A. The Siemens 6SE6440-2UD35-5FA1 has a three-phase input and output. The line voltage is 380 to 480 V AC with a tolerance of ten percent in each direction; the permissible line frequency ranges from 47 to 63 Hz. Input current and output current are to be considered separately. On the line side, the rated current is 104 A for HO and 139 A for LO. For high overload, a load of 150 percent of the output current for 60 seconds is specified, followed by 240 seconds at 100 percent. The low-overload profile states 140 percent for three seconds, then 110 percent for 57 seconds and 100 percent for 240 seconds. The pulse frequency is 4 kHz. For an order with shipping from Germany to the United States and other international destinations, the complete identifier of this FSF version is decisive. For signal processing, six digital inputs and three relay outputs are available. They are complemented by two analog inputs, two analog outputs and a PTC/KTY interface. A fan provides cooling of the unit. The permissible ambient temperature range differs by load profile: −10 to +50 °C for HO and −10 to +40 °C for LO. The enclosure corresponds to IP20 or UL Open Type. The converter measures 350 mm in width, 850 mm in height and 320 mm in depth. Its net weight is 56 kg.

Siemens 6SE6440-2UD35-5FA1 The item supplied will have the stated manufacturer or type number and the stated condition category. Serial number, manufacturing date, labels, colour, packaging and normal signs of use or storage may differ.

Specifications

Unless expressly confirmed, technical information is provided to identify the device type. The complete manufacturer or type number is decisive.

Manufacturer Siemens
Product series MICROMASTER 440
Manufacturer/order/ident number 6SE6440-2UD35-5FA1
Device type Frequency converter
Input voltage 3 AC 380–480 V ±10 %
Line frequency 47–63 Hz
Output power 55 kW HO / 75 kW LO
Output current 110 A HO / 145 A LO
Input current 104 A HO / 139 A LO
Pulse frequency 4 kHz
Overload capability HO 150 % for 60 s, then 100 % for 240 s
Digital inputs 6
Relay outputs 3
Analog inputs/outputs 2 inputs / 2 outputs
Temperature sensor interface 1 × PTC/KTY
Protection class IP20 / UL Open Type
Cooling Fan
Operating temperature −10 to +50 °C HO / −10 to +40 °C LO
Dimensions 350 × 850 × 320 mm (W × H × D)
Weight 56 kg
Control cabinet with PLC modules and automation components
Industrial production environment

Urgent requirement?

Shipping options

Send us the complete type number, destination and requested timing. We will assess whether the specific item can be supplied and which shipping options can be offered.

Any stated dispatch or delivery date is an estimate unless expressly confirmed as binding.

Contact us now!

Product safety

Manufacturer / EU responsible person

FAQ

Frequently asked questions

Contact us
What power does this MICROMASTER-440 version have?

The rated power is 55 kW at high overload and 75 kW at low overload. The associated output currents are 110 A and 145 A.

What applies if an item develops a defect within 14 days?

For the condition categories “Used, removed from an installation” and “New, old stock”, the contractual 14-day right of return in the event of a defect applies. The defect must occur within 14 calendar days after delivery and be reported in text form within the same period.

In particular, the REHA tamper-evident seal must remain fully intact and our RMA approval is required before return. In an accepted case, we decide between replacement and refund. Details in Section 11 of the Terms.

Which shipping methods and delivery times are available?

The shipping method, shipping cost and estimated delivery time are confirmed for the specific order. Depending on the item, destination and urgency, we can check parcel, express or freight shipping as well as collection.

A delivery date is binding only if we expressly confirm it as binding.

Which payment terms apply?

The payment terms stated in the checkout or order confirmation apply. Depending on the order and customer, payment is made in advance or against invoice.

International deliveries and deliveries to new customers are generally made against advance payment unless we expressly confirm another payment arrangement.

Can I return an item ordered incorrectly or found incompatible?

No. There is no general B2B right of return, exchange, cancellation or withdrawal. Incorrect or duplicate orders and a lack of suitability or compatibility with the customer’s installation are not covered by the contractual 14-day right of return in the event of a defect. Details in Section 12 of the Terms.

Can I request individual pricing for several items?

You may request an individual quotation for several items or larger quantities. We then check availability and pricing for the specific requirement; there is no entitlement to a quantity discount. Open the quick enquiry.

Do you also purchase industrial spare parts?

Yes. You can offer us automation and drive components for purchase. Please provide complete type numbers, quantities, condition details and photographs where possible.

After review, we will tell you whether a purchase is possible and on which terms. Learn more about selling industrial stock.

Receive a quotation by email

Request availability

Use the form to request item-specific price, availability and estimated delivery information.