Enter an error code to view the result
Matching entries appear here immediately, including the product series, a short description, the cause and the recommended remedy where available.
Technical error code database
Central Siemens error-code guide covering key drive series and product groups for fast technical orientation.
The search field is the fastest route to the relevant Siemens error code. Enter a code to see its meaning, series and diagnostic guidance directly on this page. The tables below provide a representative excerpt.
Matching entries appear here immediately, including the product series, a short description, the cause and the recommended remedy where available.
This page brings together Siemens error codes from several important product families in a single technical overview. This is particularly helpful if there is an error code, but the exact product group must first be classified or if several Siemens drive systems are used in parallel in a system.
Especially with series like SINAMICS G120, SINAMICS DCM 6RA80, SIMOVERT MASTERDRIVES VC, SIMOREG 6RA70 or MICROMASTER 420, 430 and 440, a central error code search saves a lot of time in the event of service. In addition, the page leads directly to further product areas and inquiries.
If you are looking for a suitable replacement device, a Siemens assembly or a technical assignment, this error code page leads directly to Siemens products and the product inquiry.
The Siemens error-code database contains 1,941 error codes from 9 product groups. This central guide focuses on the key series and product families for clear, practical orientation.
The error-code search above is the main feature of this page. It displays the relevant information directly in each result without requiring additional subpages.
The tables further down show typical and frequently searched messages for technical orientation. Use the search field above to query the complete dataset.
SINAMICS DCM 6RA80 represents the largest individual area in the data collection. Especially with DC-drives, the focus of the diagnosis is power converters, cooling, power section, network feedback and application parameters.
| Code | Display | Description | Type |
|---|---|---|---|
| Beispiel | F60001 | Internal device malfunction | Disturbance |
| Beispiel | A60010 | Temperature warning | Warning |
| Beispiel | A60020 | Communication warning | Warning |
The SINAMICS G120 product family is installed in many machines and conveyor systems. Typical topics in diagnostics are control module, parameterization, temperature, memory card and configuration errors.
| Code | Display | Description | Type |
|---|---|---|---|
| A01009 | A01009 | CU: Overtemperature control module | Warning |
| A01016 | A01016 | Firmware changed | Warning |
| A01028 | A01028 | Configuration error | Warning |
The CU230P-2 versions of the G120-Familie are particularly relevant in HVAC and pump/fan applications. Accordingly, in addition to standard errors, application-specific messages also play a role here.
| Code | Display | Description | Type |
|---|---|---|---|
| A01009 | A01009 | Overtemperature control module | Warning |
| A01035 | A01035 | Parameter backup files corrupted | Warning |
| A01045 | A01045 | Configuration data invalid | Warning |
SIMOVERT MASTERDRIVES VC systems are still in use in many existing systems. When troubleshooting, the power section, parameterization, communication and system-side releases are particularly important.
| Code | Display | Description | Type |
|---|---|---|---|
| Beispiel | F008 | DC link error | Disturbance |
| Beispiel | A015 | Cooling warning | Warning |
| Beispiel | F020 | Power section error | Disturbance |
SIMOREG 6RA70 drives are still in use in many DC-applications today. Common diagnostic fields include current control, field supply, cooling and power unit-related messages.
| Code | Display | Description | Type |
|---|---|---|---|
| Beispiel | F001 | Device malfunction | Disturbance |
| Beispiel | A005 | Temperature warning | Warning |
| Beispiel | F010 | Control error | Disturbance |
MICROMASTER 440 devices can be found in many existing systems. Typical fault topics are overcurrent, intermediate circuit, overtemperature, parameterization and motor connection.
| Code | Display | Description | Type |
|---|---|---|---|
| A05000 | A05000 | General warning | Warning |
| F0001 | F0001 | Overcurrent | Disturbance |
| F0002 | F0002 | DC link overvoltage | Disturbance |
MICROMASTER 430 is particularly common in pump and fan applications. In the event of malfunctions, the supply, setpoint control, parameterization and motor side should be thoroughly checked.
| Code | Display | Description | Type |
|---|---|---|---|
| F0001 | F0001 | Overcurrent | Disturbance |
| F0003 | F0003 | Undervoltage | Disturbance |
| A05000 | A05000 | General warning | Warning |
The MICROMASTER 420 is also one of the frequently sought-after Siemens existing devices. In everyday service, the focus here is usually on standard errors from the supply, motor side and parameterization.
| Code | Display | Description | Type |
|---|---|---|---|
| F0001 | F0001 | Overcurrent | Disturbance |
| F0002 | F0002 | Overvoltage | Disturbance |
| A05000 | A05000 | General warning | Warning |
SINAMICS V20 is widely used in the area of compact standard drives. Typical topics are overcurrent, overtemperature, power supply and parameterization.
| Code | Display | Description | Type |
|---|---|---|---|
| F1 | F1 | Overcurrent | Disturbance |
| F2 | F2 | Overvoltage | Disturbance |
| A5 | A5 | Temperature warning | Warning |
If a Siemens converter or drive system needs to be replaced at short notice, the exact assignment of the series, assembly and error pattern is particularly important. This central error code page is intended to help with exactly that: classify errors more quickly and then move on to the appropriate product or query.
Suitable overview pages such as Siemens and the product inquiry can be used for further products and assemblies.
Shop & Inquiry
After the technical classification via the error code search, the direct route to the appropriate Siemens module, to the replacement device or to the product inquiry is usually the most sensible next step.
Siemens error codes can have very different structures depending on the product group. While alphanumeric codes such as A01009 or F30005 often appear in SINAMICS, more compact displays can be found in other series. That’s why a central search page is particularly helpful.
The search bar at the top of the page is crucial for complete research. The tables below intentionally only serve as typical excerpts of the most important product groups.
This content is intended as technical orientation for qualified personnel and does not replace the official manufacturer documentation.
Work on inverters and drive systems must only be carried out by qualified electrical personnel. Isolation, residual voltage, DC-link and waiting-time requirements must always be observed.