SEW-Eurodrive 8227241
€150.00
The individual quotation states the shipping method and costs for the item and destination.
SEW-Eurodrive DFS21B is a PROFINET IO fieldbus interface with PROFIsafe. It connects suitable SEW drive systems to higher-level automation and safety controllers. Two RJ45 ports with an internal switch and auto crossing support Ethernet line topologies. The interface operates at 100 MBaud in full-duplex mode based on Ethernet II. PROFINET IO is supplemented by HTTP and SMLP services for diagnostics and commissioning; ARP and ICMP are supported as Ethernet services. External power at X26 is 24 V DC with a tolerance of −15 to +20 percent. Maximum current consumption is 200 mA and maximum power consumption is 3.4 W. The F address is adjustable from 1 to 1022 through DIP switches. The safety function reaches SIL 3 according to IEC 61508 and PL e according to EN ISO 13849-1. The system structure is 1oo2D, a two-channel architecture with diagnostics. PFHd is below 1 × 10⁻⁹ per hour. Safe digital output F-DO operates at 24 V DC with a rated current of 1 A. The individual DFS21B fieldbus module measures 140 × 100 × 30 mm in length × width × height order and weighs 0.14 kg. UOH11B is a distinct gateway housing with a different form factor. Type number, firmware, GSD file, F address and safety configuration define the module's specific configuration.
The item supplied will have the stated manufacturer or type number and the stated condition category. Serial number, manufacturing date, labels, colour, packaging and normal signs of use or storage may differ. Unless expressly confirmed, technical information is provided to identify the device type. The complete manufacturer or type number is decisive.
| Manufacturer | SEW-Eurodrive |
|---|---|
| Product series | SEW options and fieldbus modules |
| Manufacturer/order/identification number | DFS21B |
| Device type | PROFINET IO fieldbus interface with PROFIsafe |
| Power supply | 24 V DC, -15 % to +20 % |
| Maximum current consumption | 200 mA DC |
| Maximum power consumption | 3.4 W |
| Application protocols | PROFINET IO, HTTP and SMLP |
| Ethernet services | ARP and ICMP |
| Ethernet format | Ethernet II |
| Data rate | 100 MBaud, full duplex |
| Connection technology | 2 × RJ45 with internal switch and auto crossing |
| Addressing | 4-byte IP address and MAC ID |
| F address | 1–1022, adjustable through DIP switches |
| Safety class | SIL 3 according to IEC 61508 / PL e according to EN ISO 13849-1 |
| System structure | 1oo2D / two-channel with diagnostics |
| PFHd value | < 1 × 10⁻⁹ per hour |
| Safe output F-DO | 24 V DC, rated current 1 A |
| Dimensions | 140 × 100 × 30 mm (L × W × H) |
| Weight | 0.14 kg |
Urgent requirement?
Send us the complete type number, destination and requested timing. We will assess whether the specific item can be supplied and which shipping options can be offered.
Any stated dispatch or delivery date is an estimate unless expressly confirmed as binding.
Contact us now!Manufacturer / EU responsible person
Outside dimensions of the individual fieldbus module are 140 × 100 × 30 mm in length × width × height order.
Device weight of the individual DFS21B module is 0.14 kg.
For the condition categories “Used, removed from an installation” and “New, old stock”, the contractual 14-day right of return in the event of a defect applies. The defect must occur within 14 calendar days after delivery and be reported in text form within the same period.
In particular, the REHA tamper-evident seal must remain fully intact and our RMA approval is required before return. In an accepted case, we decide between replacement and refund. Details in Section 11 of the Terms.
The shipping method, shipping cost and estimated delivery time are confirmed for the specific order. Depending on the item, destination and urgency, we can check parcel, express or freight shipping as well as collection.
A delivery date is binding only if we expressly confirm it as binding.
The payment terms stated in the checkout or order confirmation apply. Depending on the order and customer, payment is made in advance or against invoice.
International deliveries and deliveries to new customers are generally made against advance payment unless we expressly confirm another payment arrangement.
No. There is no general B2B right of return, exchange, cancellation or withdrawal. Incorrect or duplicate orders and a lack of suitability or compatibility with the customer’s installation are not covered by the contractual 14-day right of return in the event of a defect. Details in Section 12 of the Terms.
You may request an individual quotation for several items or larger quantities. We then check availability and pricing for the specific requirement; there is no entitlement to a quantity discount. Open the quick enquiry.
Yes. You can offer us automation and drive components for purchase. Please provide complete type numbers, quantities, condition details and photographs where possible.
After review, we will tell you whether a purchase is possible and on which terms. Learn more about selling industrial stock.
Receive a quotation by email
Use the form to request item-specific price, availability and estimated delivery information.